65kVA Power Unit
Stork’s transformer units (Mannings model) have achieved a worldwide reputation for cost effective design, quality and reliability having been successfully operated on heat treatment projects in some of the most demanding climates and industrial environments around the world, for over 50 years.
Part no.11100
Product detail
Product specifications
Description
Stork’s transformer units (Mannings model) have achieved a worldwide reputation for cost effective design, quality and reliability having been successfully operated on heat treatment projects in some of the most demanding climates and industrial environments around the world, for over 50 years.
The 65kVA unit consists of a robust, natural air cooled, 3 phase transformer which is built into a compactly designed, strong, steel case which together provide the unit with a long working life expectancy. Each output channel is controlled by means of an internal energy regulator working in parallel with a digital temperature controller. Provision is also made for connection to external control from any compatible programmer/control unit. Switching between internal (manual) control or external (automatic) control mode is made via each channel’s auto/manual selector switch.
The 65kVA unit consists of a robust, natural air cooled, 3 phase transformer which is built into a compactly designed, strong, steel case which together provide the unit with a long working life expectancy. Each output channel is controlled by means of an internal energy regulator working in parallel with a digital temperature controller. Provision is also made for connection to external control from any compatible programmer/control unit. Switching between internal (manual) control or external (automatic) control mode is made via each channel’s auto/manual selector switch.
Specifications
TRANSFORMER CORE
- Three Phase, Air Natural, Class ‘H’, 50kV
- Primary winding connected in Delta
- Secondary winding connected in Star
PRIMARY SUPPLY
- Primary voltage: 380V, 415V, 440V
- Primary current: 106A, 97A, 92A
- Frequency: 50/60 Hz
PROTECTION
- Three phase 100A circuit breaker with shunt trip
- Three primary core winding over temperature thermostats linked to circuit breaker shunt trip
SECONDARY OUTPUTS
- Output: 65V
- 6 temperature controlled output channels
- Max load per output channel: four 60V, 2.7kW heating elements
- Maximum current per output channel: 180A
- Auxiliary Output: Two 110V, 5A, 50/60Hz fused output sockets
CONTROL
- Six 110V Energy Regulators
- Six 110V Temperature Controllers
- One Multi-pin socket for remote programmer
- Mode Selection: Six Auto / Manual switches
- Indicators: Six 110V neon channel indicators
MAINS CONNECTION
- The units are complete with 4.5m of four core primary cable
SWITCHING
- Contactorised – six off 200A, 110V a.c. solenoid contactors
CONSTRUCTION
- Case: Robust sheet steel case complete with four 150mm diameter wheels
- Lifting Method: Fork lift under base
DIMENSIONS
- Weight: 302kg
- Case Dimensions:
Height: 1010mm
Width: 675mm
Depth: 725mm
Category | HT Units |
---|---|
Power kVA | 50 kVA |
Voltage | 380 / 415 / 440 V |
Current | 106 / 97 / 92 A |
Frequency | 50 / 60 Hz |
# Output Channels | 6 |
Temp. Controller | Mannings |
Analog/Digital | Analog |