Ceramic Fibre Thermal Insulation Blankets

Ceramic fibre insulation blankets help to ensure the desired temperature is reached, reduce heat losses away from the edge of the heaters, and provide personnel protection
Ceramic Fibre Thermal Insulation Blankets for heat treatment - help to ensure the desired temperature is reached, reduce heat losses away from the edge of the heaters, and provide personnel protection

DESCRIPTION

Ceramic fibre thermal insulation blankets are used to cover the heating elements on a heat treatment set up to help ensure the desired temperature is reached, reduce heat losses away from the edge of the heaters, and provide personnel protection. These ceramic fibre insulation blankets are supplied wrapped in stainless steel mesh which improves reusability of the insulation.

Contact for the Meshed/Unmeshed options.

Specifications

Density, kg/m³Thickness, mmWidth, mmLength, mm
96196001000
9625300600
9625300900
9625600600
9625600900
96256001200
96256001800
96256007300
12825300600
12825300900
12825600600
12825600900
128256001200
128256001800
128256007300

Transformer core

  • Three phase, forced air cooled, class H, 50kVA
  • Primary winding connected in Delta
  • Secondary winding connected in Star
  • Auxiliary winding: 110V a.c. 3.3kVA single phase

Primary supply

  • Primary voltage: 380V, 415V, 440V
  • Primary current: 76A, 70A, 66A
  • Frequency: 50/60 Hz

Protection

  • Three phase 80A circuit breaker with shunt trip
  • Three primary core winding over temperature thermostats linked to circuit breaker shunt trip

Secondary outputs

  • Output: 32.5V – 0V – 32.5V (for 30V and 60V heating element operation)
  • Auxiliary outputs: Two 110V, 10A, 50/60Hz output sockets
  • Number of temperature controlled output channels: 6 channels
  • Maximum load per output channel: 8.1kW (e.g. three 60V, 2.7kW heating elements)
  • Maximum current per output channel: 135A

Switching

  • Six double pole, 180A, contractors with 110V a.c. coil

Temperature control

  • Temperature measurement, display and control
  • Degrees Fahrenheit or Degrees Centigrade
  • Start temperature
  • Temperature ramp up and down in degrees per hour
  • Hold/soak temperature set point and hold/soak time period setting

Temperature recording

  • Ambient temperature: Minus 0˚C to 50˚C
  • Humidity: 20% to 80% RH, non-condensing is required (temperature x humidity < 3200)
  • Environmental protection: IEC IPSO (front door of panel mounted unit)
  • Input points: 12 Points
  • Input thermocouple types: Thermocouple inputs- K,
  • Reference range: Type K: -200˚C to 1370˚C (-326˚F to 249˚F)
  • Printing system: Ink jet system, 6 colour
  • Chart Width: 180mm
  • Chart Length: Z fold 20m
  • Chart Speed: 5 to 300mm per hour

Construction

  • Case: 304 Stainless Steel case fitted with four 150mm nylon wheels

Dimensions

  • Weight: 355kg
  • Case Dimensions:
    Height: 1545mm
    Width: 680mm
    Depth: 665mm

Interested in this product?

Let's have a talk! Our experts take the time to discuss your existing challenges and help you make smart decisions that best meet your needs.

Get in Touch