Heating Element Core Wires

Heating element core wire and cold tail wire is for repair and manufacture of ceramic pad heating elements
Heating element core wire and cold tail wire is for repair and manufacture of ceramic pad heating elements

DESCRIPTION

Most resistance wire heating elements use nichrome 80/20 (80% nickel, 20% chromium) in wire, ribbon, or strip form.

NiCr is an ideal material because it has relatively high resistance. Contact us for further information.

Specifications

MaterialCeramic pad/channelType
Nickel ChromeCeramic pad19 Strand 60:16
Nickel ChromeCeramic pad19 Strand 80:20
NickelCeramic pad19 Strand 212

Transformer core

  • Three phase, forced air cooled, class H, 50kVA
  • Primary winding connected in Delta
  • Secondary winding connected in Star
  • Auxiliary winding: 110V a.c. 3.3kVA single phase

Primary supply

  • Primary voltage: 380V, 415V, 440V
  • Primary current: 76A, 70A, 66A
  • Frequency: 50/60 Hz

Protection

  • Three phase 80A circuit breaker with shunt trip
  • Three primary core winding over temperature thermostats linked to circuit breaker shunt trip

Secondary outputs

  • Output: 32.5V – 0V – 32.5V (for 30V and 60V heating element operation)
  • Auxiliary outputs: Two 110V, 10A, 50/60Hz output sockets
  • Number of temperature controlled output channels: 6 channels
  • Maximum load per output channel: 8.1kW (e.g. three 60V, 2.7kW heating elements)
  • Maximum current per output channel: 135A

Switching

  • Six double pole, 180A, contractors with 110V a.c. coil

Temperature control

  • Temperature measurement, display and control
  • Degrees Fahrenheit or Degrees Centigrade
  • Start temperature
  • Temperature ramp up and down in degrees per hour
  • Hold/soak temperature set point and hold/soak time period setting

Temperature recording

  • Ambient temperature: Minus 0˚C to 50˚C
  • Humidity: 20% to 80% RH, non-condensing is required (temperature x humidity < 3200)
  • Environmental protection: IEC IPSO (front door of panel mounted unit)
  • Input points: 12 Points
  • Input thermocouple types: Thermocouple inputs- K,
  • Reference range: Type K: -200˚C to 1370˚C (-326˚F to 249˚F)
  • Printing system: Ink jet system, 6 colour
  • Chart Width: 180mm
  • Chart Length: Z fold 20m
  • Chart Speed: 5 to 300mm per hour

Construction

  • Case: 304 Stainless Steel case fitted with four 150mm nylon wheels

Dimensions

  • Weight: 355kg
  • Case Dimensions:
    Height: 1545mm
    Width: 680mm
    Depth: 665mm